Air Tightness Testing Across Wales / Profion Aer ledled Cymru
Compliant airtightness testing for new-build, low-energy and existing homes. Services include pre-completion testing, final certification and smoke diagnostics to identify air leakage and improve building performance. Delivered by an Elmhurst-approved Level 1 Airtightness Tester.
Complete New Build Energy Compliance Package -
SAP assessment and airtightness testing from one consultant
Design-stage SAP Assessment ➜ Construction-stage Advice ➜ Optional Mid-construction Airtightness Diagnostics Test ➜ Final Mandatory Airtightness Test ➜ As-built SAP Assessment ➜ EPC
Keeping these services together reduces duplicated information, improves continuity and helps avoid unexpected compliance problems at completion.
MID-CONSTRUCTION TESTING
Early testing while the airtight layer remains accessible helps identify leakage before finishes are completed. This is particularly valuable for low-energy homes, challenging airtightness targets and unfamiliar construction systems.
EXISTING-BUILDING TESTING
Blower-door testing and smoke diagnostics can be used to locate leakage in existing homes, conversions and retrofit projects. The findings help inform remedial work and verify improvements.
FINAL COMPLIANCE TESTING
Mandatory airtightness testing and certification for new dwellings and other buildings where required under the Building Regulations. The test result can be coordinated directly with the as-built SAP assessment and EPC.
WHAT IS AN AIRTIGHTNESS TEST?
An airtightness test measures the amount of uncontrolled air leakage through gaps and cracks in the building envelope. It helps demonstrate compliance with Part L, identify workmanship issues and assess how effectively the building retains heat.
Testing can be carried out during construction to locate leaks while they remain accessible, or at completion to provide the final result required for Building Regulations and the as-built SAP assessment.
TESTING PROCESS
From Booking to Certification
Project review
You provide the drawings, site address, envelope area or dimensional information, target airtightness result and anticipated test date.
⇣
Pre-test preparation
A test-preparation checklist is issued beforehand so the building team can ensure the property is ready for testing.
⇣
On-site testing
The blower-door equipment is installed in an external doorway and the building is tested across a series of pressure differences in accordance with the relevant testing standard.
⇣
Results and certification
The result is calculated and discussed on site. Subject to a valid test, the airtightness certificate is issued for Building Control and the final SAP assessment.
WHY APPOINT AER ?
Building-construction experience
As a Chartered Architectural Technologist, I understand airtightness details, construction sequencing and the common junctions where air leakage occurs.
Practical diagnostic advice
Where leakage is identified, I can help the site team locate likely problem areas and recommend practical remedial measures.
Coordinated compliance
Airtightness testing and SAP assessments can be managed through one consultant, reducing delays at project completion.
Professional testing service
Testing is undertaken using calibrated equipment and the appropriate CIBSE-TM23 / ATTMA methodology, with certification issued for valid compliance tests.
Coverage across Wales
Based in West Wales and supporting architects, developers, contractors, housing associations and self-builders across much of Wales.
"Professional service from Dafydd and cost effective. Thanks."
★★★★★
Hook Construction Ltd - Neyland, Pembrokeshire.
CONTACT /CYSYLLTWCH
Dafydd@AERbuildingperformance.co.uk
07837739100 (8am-5pm Monday to Friday)
© 2025. All rights reserved.


Dafydd Morgan MCIAT
Elmhurst Approved Level 1 Airtightness Tester